Menu
Your Cart

Teledyne FLIR A310 (< 9Hz) 18mm Lens 25° FoV Thermal Imaging Camera

DISCONTINUED PRODUCT

Teledyne FLIR A310 (< 9Hz) 18mm Lens 25° FoV Thermal Imaging Camera
Highlights:

FLIR A310 (9Hz) Thermal Imaging Camera

  • IP Thermography Camera
  • 320x240 Resolution
  • 9Hz
  • 25°(H) × 18.8°(V) FOV
  • MPEG-4 Streamed Video
  • Multiple Lens Options

$0.00
  • : We usually have a majority of these items in stock.
    Please call or contact us for availability.
  • SKU: 42701-1101

Available Options

FLIR A310 (9Hz)

Thermal Imaging Camera

The FLIR A310 is a fixed-mounted thermal imaging camera that can be installed almost anywhere to monitor your critical equipment and other valuable assets. The camera can safeguard your plant and measure temperature differences to assess the criticality of a given situation. This allows you to see problems before they become costly failures, preventing downtime and enhancing worker safety.


Monitor Your Critical Equipment

EXCELLENT IMAGE QUALITY

The FLIR A310 features a 320 x 240 pixel vanadium oxide (VOx) microbolometer that detects temperature differences as small as 50 mK.

INDUSTRIAL PROTOCOLS

Ethernet/IP, Modbus TCP compliant for sharing analysis and alarm results to a PLC; digital inputs/outputs are available for alarms, external equipment control.

BUILT-IN ANALYSIS & ALARM

The A310 offers spot, area, and difference temperature measurement, and can alarm as a function of analysis, internal temperature, or digital input.

FLIR A310 (9Hz) Key Features

  • MPEG-4 streaming
  • PoE (Power over Ethernet)
  • Built-in web server
  • General purpose I/O
  • 100Mbps Ethernet (100m cable, wireless, fiber, etc.)
  • Synchronization through SNTP
  • Composite video output
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included
INFORMATION
Specifications
Imaging and optical data
IR resolution 320 x 240 pixels
Thermal sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Field of view (FOV) 25° × 18.8°
Minimum focus distance 0.04 m (1.31 ft.)
Focal length 18 mm (0.7 in.)
Spatial resolution (IFOV) 1.36 mrad
Lens identification Automatic
F-number 1.3
Image frequency 9 Hz
Focus Automatic or manual (built in motor)
Zoom 1-8x continuous, digital, interpolating zooming on images
Detector data  
Detector type Focal plane array (FPA), uncooled microbolometer
Spectral range 7.5–13 µm
Detector pitch 25µm
Detector time constant Typical 12 ms
Measurement  
Object temperature range
  • –20 to +120°C (–4 to +248°F)
  • 0 to +350°C (+32 to +662°F)
Accuracy ±2°C (±3.6°F) or ±2% of reading
Measurement analysis  
Spotmeter 10 (with no image streaming)
Area 10 boxes with max./min./average/position (with no image streaming)

Isotherm

1 with above/below/interval
Measurement option Measurement Mask Filter
Schedule response: File sending (ftp), email (SMTP)
Difference temperature Delta temperature between measurement functions or reference temperature
Reference temperature Manually set or captured from any measurement function
Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reflected apparent temperature correction Automatic, based on input of reflected temperature
External optics/windows correction Automatic, based on input of optics/window transmission and temperature
Measurement corrections Global and individual object parameters
Alarm  
Alarm Functions 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Set-up  
Color palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up commands Date/time, Temperature (°C/°F)
Storage of images Built-in memory for image storage
Storage media Standard JPEG, 16-bit measurement data included
File formats  
Ethernet  
Ethernet Control, result and image
Ethernet, type 100 Mbps
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, communication TCP/IP socket-based FLIR proprietary
Ethernet, video streaming

JPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5

Ethernet, image streaming 16-bit 320 × 240 pixels @ 4.5Hz
• Radiometric
Ethernet power

Power over Ethernet, PoE IEEE 802.3af class 0.

NOTE: In cameras manufactured before 2013, due to an error in the implementation of power over Ethernet, in some rare cases the
camera will not be powered. In such cases, power the camera using the external power cable, or modify the camera according to Service bulletin SB14-006.
Ethernet, protocols

Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP,
HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP

Digital input/output  
Digital input, purpose Image tag (start/stop/general), Input ext. device (programmatically read)
Digital input 2 opto-isolated, 0–1.5 V = low, 3–25 V = high
Digital output, purpose As function of ALARM, Output to ext. device (programmatically set)
Digital output 2 opto-isolated, ON = supply (max. 100 mA), OFF = open
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 6–24 VDC, max. 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Composite video  
Video out Composite video output, PAL and NTSC compatible
Video, standard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Video, connector type Standard BNC connector
Power system  
External power operation 12/24 VDC, 24 W absolute max.
External power, connector type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC
Environmental data  
Operating temperature range –15°C to +50°C (+5°F to +122°F)
Storage temperature range –40°C to +70°C (–40°F to +158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
EMC
  • EN 61000-6-2:2001 (Immunity)
  • EN 61000-6-3:2001 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
Encapsulation IP 40 (IEC 60529)
Shock 25 g (IEC 60068-2-27)
Vibration 2 g (IEC 60068-2-6)
Physical data  
Weight 0.7 kg (1.54 lb.)
Camera size (L × W × H) 170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)
Tripod mounting UNC ¼"-20 (on three sides)
Base mounting 2 × M4 thread mounting holes (on three sides)
Housing material Aluminum
What\'s in the Box  
List of contents
            • Infrared camera with lens
            • Ethernet cable
            • Mains cable
            • Power cable, pig-tailed
            • Power supply
            • Printed documentation
            • Utility CD-ROM
What's In The Box

FLIR A300 Series Thermal Camera What's in the Box


Lens Comparison
Lens Options
  IR Lens , 15° FOV, 30mm
(1196961)
IR lens, 45° FOV, 10mm
(1196960)
IR lens, 6° FOV, 76mm
(T197407)
IR lens, 90° FOV, 4mm
(T197411)
Close-Up Lens
4X (100μm)
(T197215)
Close-up Lens
2x (50 µm)
(T197214)
Close-up Lens
1x (25 µm)
(T97415)
Imaging and Optical Data
Field of View (FoV) 15°(H)×11.25°(V)
45°(H)×33.8°(V)
(H)×4.5°(V)
90°(H)×73°(V)
32°(H)×24°(V)
16°(H)×12°(V)
(H)×6°(V)
Minimum focus distance 1.2 m (3.93 ft.) 0.20 m (19.69 in.) 4 m (13.11 ft.) 40 mm (5.91 in.) - - -
Magnifying factor - - - -
Working Distance - - - - 79 mm 33 mm 20 mm
Depth of Field - - - - ±2.0 mm ±0.4 mm ±0.15 mm
Focal length 30.38 mm (1.2 in.) 9.66 mm (0.38 in.) 76 mm (3.0 in.) 4 mm (0.157 in.) 73 mm (2.9 in.) 37 mm (1.5 in.) 18.2 mm (0.72 in.)
Spatial resolution (IFOV) Depends on the IR resolution of the camera:
1.65 mrad for 160 × 120 pixels
1.32 mrad for 200 × 150 pixels
1.10 mrad for 240 × 180 pixels
0.82 mrad for 320 × 240 pixels
Depends on the IR resolution of the camera:
5.18 mrad for 160 × 120 pixels
4.14 mrad for 200 × 150 pixels
3.45 mrad for 240 × 180 pixels
2.59 mrad for 320 × 240 pixels
0.33 mrad 6.3 mrad Depends on the IR resolution of the camera:
200 μm for 160 × 120 pixels
160 μm for 200 × 150 pixels
133 μm for 240 × 180 pixels
100 μm for 320 × 240 pixels
Depends on the IR resolution of the camera:
100 μm for 160 × 120 pixels
80 μm for 200 × 150 pixels
67 μm for 240 × 180 pixels
50 μm for 320 × 240 pixels
25 µm
F-number 1.3 1.3 1.3 1.3 1.3 1.3 1.3
Number of Lenses - - 3 (3 asph) 3 (3 asph) 2 (2 asph) 2 (2 asph) 3 (3 asph)
MTF @ 70% of FOV - - Normal requirements (52%) Normal requirements (52%) Normal requirements (52%) Normal requirements (52%) Normal requirements (52%)
Distortion - - 3% 5% 3% 3% 3%
Lens Note - The lens and mounting support
does not mechanically fit the
FLIR T/Bxxx series.
Physical data
Weight 0.092 kg (0.203 lb.)
incl. two lens caps
0.105 kg (0.231 lb.)
incl. two lens caps
Lens: 0.328 kg (0.723 lb.)
Support: 0.15 kg (0.331 lb.)
Lens: 0.262 kg (0.578 lb.)
Support: 0.048 kg (0.106 lb.)
0.11 kg (0.24 lb.) 0.11 kg (0.24 lb.) 0.38 kg (0.83 lb.)
Size (L×D) 24 × 58 mm
(1.0 × 2.3 in.)
38 × 47 mm
(1.5 × 1.9 in.)
106 × 89 mm
(4.17 × 3.48 in.)
excluding support
90 × 60 mm
(3.54 × 2.36 in.)
excluding support
35.2 × 55 mm 35.2 × 55 mm 167 × 60 mm
EAN-13 7332558001134 7332558001141 7332558005804 7332558005538 7332558005088 7332558005095 7332558005958

We also recommend

Teledyne FLIR A300 (30Hz) 18mm Lens 25° FoV Thermal Imaging Camera
25° HFoV | 18mm A300
SKU: 48201-1001
FLIR A300 (30Hz) Thermal Imaging Camera The FLIR A300 18mm thermal imaging camera is the standard model in the A-Series offering an affordab..
$9,458.90
Teledyne FLIR A310 (30Hz) 18mm Lens 25° FoV Thermal Imaging Camera
25° HFoV | 18mm A310
SKU: 48201-1101US
FLIR A310 (30Hz) Thermal Imaging Camera The FLIR A310 is a fixed-mounted thermal imaging camera that can be installed almost anywhere to mon..
$0.00
SKU: 48201-1201
FLIR A320 Tempscreen FIXED-MOUNT THERMAL CAMERA FOR ELEVATED SKIN TEMPERATURE SCREENING The FLIR A320 Tempscreen camera is preconfigured for monitor..
$17,961.90

Recently Viewed

Teledyne FLIR A310 (< 9Hz) 18mm Lens 25° FoV Thermal Imaging Camera
25° HFoV | 18mm A310
SKU: 42701-1101
FLIR A310 (9Hz) Thermal Imaging Camera The FLIR A310 is a fixed-mounted thermal imaging camera that can be installed almost anywhere to moni..
$0.00
FLIR Boson 640