FLIR A400/700 Streaming Series

FLIR A400/A700 THERMAL IMAGE STREAMING CAMERA
FLIR A400/A700 THERMAL IMAGE STREAMING CAMERA
 
Image and Optical Data A400 Series A700 Series
IR Resolution 320 × 240 640 x 480
Visual resolution* 1280 × 960
Thermal Sensitivity (NETD) Depending on lens used; see lens specification
Field of view (FOV)

70mm/6°, 29mm/14°, 17mm/24°, 17mm/24° Macro, and 10mm/42°

  *Denotes Horizontal Field of View
Thermal Resolution <30 mK to <50 mK, lens dependent
Spatial resolution (IFOV) 1.4 mrad/pixel
IR Camera Focus One-shot contrast, motorized, manual
Measurement
Object temperatures -20°C to 2000°C (-4°F to 3632°F), 3 ranges
Accuracy ±2°C (±3.6°F) or ±2% of reading
Measurement Analysis A400/A700 Series
  Standard Configuration Advanced Configuration*
Standard functions 10 spotmeters, 10 boxes, 3 Deltas, 1 isotherm, 1 iso-coverage, 1 reference temperature 10 spotmeters, 10 boxes & mask polygons, 3 Deltas, 2 isotherm, 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline
Automatic hot/cold detection Max./min. temperature value and position shown within box
Scheduled response sftp (image), SMTP (image and/or measurement data/result)
Measurement frequency Up to 10 Hz
Measurement result read-out Yes; common protocols include Ethernet/IP,
Modbus TCP, MQTT, and REST API
Alarm
Alarm function On any selected measurement function; digital in;
internal camera temperature
Alarm output Yes: common output includes e-mail, EtherNet/IP,
Modbus TCP, and RESTful API
Video Streaming, RTSP Protocol
Unicast -- Yes
Multicast -- Yes
Multiple image streams -- Yes
Video Stream 0
Source -- Visual, IR, MSX®
Contrast enhancement -- FSX®, histogram equalization (IR only)
Overlay -- With, without
Pixel format -- YUV411
Encoding -- H.264/MPEG4/MJPEG
Video Stream 1  
Source -- Visual, IR, MSX®
Overlay -- No
Pixel format -- YUV411
Encoding -- H.264/MPEG4/MJPEG
Radiometric Streaming, RTSP
  Standard Configuration Advanced Configuration*
Source -- IR
Pixel format -- MONO 16
Encoding

--

Compressed JPEG-LS;
FLIR Radiometric
Video/radiometric streaming, GVSP (GigE Vision) protocol
Unicast -- Yes
Multicast -- Yes
Multiple image streams

--

No

Video stream 0 Standard Configuration Advanced Configuration*
Resolution Visual, IR, MSX®, 640 × 480 pixels
Contrast enhancement FSX® (optional), histogram equalization (IR only)
Overlay

With, without

Pixel format YUV411 or MONO 8
Encoding Uncompressed
Radiometric streaming, GVSP  
Resolution 320 × 240 640 × 480
Source IR
Pixel format

MONO 16

Encoding FLIR radiometric;
temperature linear
Compressed JPEG-LS;
FLIR radiometric;
temperature linear
Ethernet
Interface Wired; Wi-Fi*
Connector types M12 8-pin X-coded, female; RP-SMA, female
Ethernet type & standard 1000 Mbps, IEEE 802.3
Ethernet power Power over Ethernet, PoE IEEE 802.3af class 3
Ethernet protocols Include EtherNet/IP, Modbus TCP, and MQTT
Digital input/output
Connector type M12 Male 12-pin A-coded (shared with ext. power)
Digital input 2× opto-isolated, Vin (low) = 0-1.5 V, Vin (high) = 3-25 V
Digital output 3× opto-isolated, 0–48 VDC, max. 350 mA (derated to 200 mA at
60°C). Solid-state opto relay, 1× dedicated as fault output (NC)
Power system
Connector type M12 Male 12-pin A-coded (shared with Digital I/O)
Power consumption 7.5 W at 24 V DC typical; 7.8 W at 48 V DC typical;
8.1 W at 48 V PoE typical
Wi-Fi*
Connector type Female RP-SMA
 
*Optional Feature
The FLIR A-Series cameras are designed for configuration to your specific needs.
Set Descending Direction
View as Grid List

2 Items

per page
Set Descending Direction
View as Grid List

2 Items

per page