FLIR A300 (9Hz) Thermal Imaging Camera

FLIR A300 (9Hz) 18mm Lens 25° FoV Thermal Imaging Camera

RHP International will be closed for the Independence Day Holiday Friday July 3rd, 2020 and will be open Monday, July 6th, 2020.
Purchases made during this time, will be processed when we return Monday, July 6th, 2020.
HS-324 with 2X Extender

FLIR HS-307 Command

FLIR DUO - The world' s most compact dual-sensor thermal imager for drones

FLIR DUO Dual Thermal Imager

FLIR A300 (9Hz) 18mm Lens 25° FoV Thermal Imaging Camera

FLIR A300 (9Hz) 18mm Lens 25° FoV Thermal Imaging Camera Highlights:
  • IP Thermography Camera
  • 320x240 Resolution
  • 9Hz
  • 25°(H) × 18.8°(V) FOV
  • MPEG-4 streaming.
  • PoE (Power over Ethernet).
  • Built-in web server.
  • General purpose I/O.
  • 100 Mbps Ethernet (100 m cable, wireless, fiber, etc.).
  • Synchronization through SNTP.
  • Composite video output.
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included.
  • Open and well-described TCP/IP protocol for control and set-up.
  • 16-bit 320 × 240 pixel images at 3 Hz, radiometric.
  • Lenses: 25° included, 15° and 45° optional.
$7,995.00
SKU
42701-1001
This Thermal Camera is export controlled. More Information

FLIR A300

Thermal Imaging Camera

The FLIR A300 18mm thermal imaging camera is the standard model in the A-Series offering an affordable and accurate temperature measurement solution for basic applications.
The FLIR A300 18mm thermal imaging camera comes with a 18mm standard lens providing a 25°×19° field of view and 320×240 resolution.
Outfitted with its composite video output, the FLIR A300 18mm thermal camera is an excellent choice for a variety of infrared imaging needs such as safety inspections, medical and veterinary uses, fire safety, automotive, food processing, and for the oil and gas industries.


Temperature Monitoring You Can See

Medical

Infrared thermography is based on analysis of skin surface temperatures as a reflection of normal or abnormal human physiology using a high performance infrared camera.

Safety

In oil/gas production, power generation or distribution there is a need to prevent and detect fires fast and automatically. A fix mounted infrared camera can be installed discretely and almost anywhere to monitor your business.

Education

FLIR infrared cameras are being used in university laboratories where high-end academic and applied research is on-going in a wide range of disciplines.


Veterinarian

An animal's body creates heat that fluctuates throughout the body depending on blood flow. The body's recognition of injury and a subsequent increase in blood flow can happen even before the animal shows signs of pain, and other conditions.

Automation

For the automotive industry the ability to continuously and automatically ensure quality is of great importance. A fix mounted infrared camera can be installed almost anywhere to monitor your production process.

Manufacturing

IR cameras made by FLIR have become indispensable tools for many engineering disciplines, particularly in advanced product development.

FLIR A300 (9Hz) Key Features

  • MPEG-4 streaming
  • PoE (Power over Ethernet)
  • Built-in web server
  • General purpose I/O
  • 100Mbps Ethernet (100m cable, wireless, fiber, etc.)
  • Synchronization through SNTP
  • Composite video output
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included
Imaging and optical data
IR resolution 320 × 240 pixels
Thermal sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Field of view (FOV) 25° × 18.8°
Minimum focus distance 0.4 m (1.31 ft.)
Focal length 18 mm (0.7 in.)
Spatial resolution (IFOV) 1.36 mrad
Lens identification Automatic
F-number 1.3
Image frequency 9 Hz
Focus Automatic or manual (built in motor)
Zoom 1–8× continuous, digital, interpolating zooming on images
Detector data  
Detector type Focal plane array (FPA), uncooled microbolometer
Spectral range 7.5–13 µm
Detector pitch 25 µm
Detector time constant Typical 12 ms
Measurement  
Object temperature range
  • –20 to +120°C (–4 to +248°F)
  • 0 to +350°C (+32 to +662°F)
Accuracy ±2°C (±3.6°F) or ±2% of reading
Set-up  
Color Palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up Commands Date/time, Temperature (°C/°F)
Storage of images  
Storage media Built-in memory for image storage
File formats Standard JPEG, 16-bit measurement data included
Ethernet  
Ethernet Control and image
Ethernet, type 100 Mbps
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, communication TCP/IP socket-based FLIR proprietary
Ethernet, image streaming

16-bit 320 × 240 pixels @ 3 Hz

            • Radiometric

           

Ethernet Power

Power over Ethernet, PoE IEEE 802.3af class 0.

NOTE: In cameras manufactured before 2013, due to an error in the implementation of power over Ethernet,
in some rare cases the camera will not be powered. In such cases, power the camera using the external power cable,
or modify the camera according to Service bulletin SB14-006.

Ethernet, protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp,
SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Digital input/output  
Digital input, purpose Image tag (start, stop, general), Image flow control, (stream on/off), Input ext. device (programmatically read)
Digital input 2 opto-isolated, 0–1.5 V = low, 3–25 V = high
Digital output, purpose Output to ext. device (programmatically set)
Digital output 2 opto-isolated, ON = supply (max. 100 mA), OFF = open
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 6–24 VDC, max. 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Composite Video  
Video Out Composite video output, PAL and NTSC compatible
Video, standard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Video, connector type Standard BNC connector
Power system  
External power operation 12/24 VDC, 24 W absolute max.
External power, connector type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC
Environmental data  
Operating temperature range –15°C to +50°C (+5°F to +122°F)
Storage temperature range –40°C to +70°C (–40°F to +158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
EMC
  • EN 61000-6-2:2001 (Immunity)
  • EN 61000-6-3:2001 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
Encapsulation IP 40 (IEC 60529)
Shock 25 g (IEC 60068-2-27)
Vibration 2 g (IEC 60068-2-6)
Physical data  
Weight 0.7 kg (1.54 lb.)
Camera size (L × W × H) 170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)
Tripod mounting UNC ¼"-20 (on three sides)
Base mounting 2 × M4 thread mounting holes (on three sides)
Housing material Aluminum
What's in the Box  
List of contents
            • Infrared camera with lens
            • Ethernet cable
            • Mains cable
            • Power cable, pig-tailed
            • Power supply
            • Printed documentation
            • Utility CD-ROM

FLIR A300 Series Thermal Camera What's in the Box

Click Photo to Enlarge


Lens Options
  IR Lens , 15° FOV, 30mm
(1196961)
IR lens, 45° FOV, 10mm
(1196960)
IR lens, 6° FOV, 76mm
(T197407)
IR lens, 90° FOV, 4mm
(T197411)
Close-Up Lens
4X (100μm)
(T197215)
Close-up Lens
2x (50 µm)
(T197214)
Close-up Lens
1x (25 µm)
(T97415)
Imaging and Optical Data
Field of View (FoV) 15°(H)×11.25°(V)
45°(H)×33.8°(V)
(H)×4.5°(V)
90°(H)×73°(V)
32°(H)×24°(V)
16°(H)×12°(V)
(H)×6°(V)
Minimum focus distance 1.2 m (3.93 ft.) 0.20 m (19.69 in.) 4 m (13.11 ft.) 40 mm (5.91 in.) - - -
Magnifying factor - - - -
Working Distance - - - - 79 mm 33 mm 20 mm
Depth of Field - - - - ±2.0 mm ±0.4 mm ±0.15 mm
Focal length 30.38 mm (1.2 in.) 9.66 mm (0.38 in.) 76 mm (3.0 in.) 4 mm (0.157 in.) 73 mm (2.9 in.) 37 mm (1.5 in.) 18.2 mm (0.72 in.)
Spatial resolution (IFOV) Depends on the IR resolution of the camera:
1.65 mrad for 160 × 120 pixels
1.32 mrad for 200 × 150 pixels
1.10 mrad for 240 × 180 pixels
0.82 mrad for 320 × 240 pixels
Depends on the IR resolution of the camera:
5.18 mrad for 160 × 120 pixels
4.14 mrad for 200 × 150 pixels
3.45 mrad for 240 × 180 pixels
2.59 mrad for 320 × 240 pixels
0.33 mrad 6.3 mrad Depends on the IR resolution of the camera:
200 μm for 160 × 120 pixels
160 μm for 200 × 150 pixels
133 μm for 240 × 180 pixels
100 μm for 320 × 240 pixels
Depends on the IR resolution of the camera:
100 μm for 160 × 120 pixels
80 μm for 200 × 150 pixels
67 μm for 240 × 180 pixels
50 μm for 320 × 240 pixels
25 µm
F-number 1.3 1.3 1.3 1.3 1.3 1.3 1.3
Number of Lenses - - 3 (3 asph) 3 (3 asph) 2 (2 asph) 2 (2 asph) 3 (3 asph)
MTF @ 70% of FOV - - Normal requirements (52%) Normal requirements (52%) Normal requirements (52%) Normal requirements (52%) Normal requirements (52%)
Distortion - - 3% 5% 3% 3% 3%
Lens Note - The lens and mounting support
does not mechanically fit the
FLIR T/Bxxx series.
Physical data
Weight 0.092 kg (0.203 lb.)
incl. two lens caps
0.105 kg (0.231 lb.)
incl. two lens caps
Lens: 0.328 kg (0.723 lb.)
Support: 0.15 kg (0.331 lb.)
Lens: 0.262 kg (0.578 lb.)
Support: 0.048 kg (0.106 lb.)
0.11 kg (0.24 lb.) 0.11 kg (0.24 lb.) 0.38 kg (0.83 lb.)
Size (L×D) 24 × 58 mm
(1.0 × 2.3 in.)
38 × 47 mm
(1.5 × 1.9 in.)
106 × 89 mm
(4.17 × 3.48 in.)
excluding support
90 × 60 mm
(3.54 × 2.36 in.)
excluding support
35.2 × 55 mm 35.2 × 55 mm 167 × 60 mm
EAN-13 7332558001134 7332558001141 7332558005804 7332558005538 7332558005088 7332558005095 7332558005958