FLIR A35 60mm Thermal Imaging Camera

FLIR A35 60mm Thermal Imaging Camera

SKU#: 74360-0101
$5,295.00

(In stock)

  • FLIR A35 60mm Thermal Imaging Camera FLIR A35 60mm Thermal Imaging Camera
  • FLIR A35 60mm Thermal Imaging Camera Rear View FLIR A35 60mm Thermal Imaging Camera Rear View
  • FLIR A35 60mm Thermal Imaging Camera Front View FLIR A35 60mm Thermal Imaging Camera Front View
  • FLIR A35 60mm Thermal Imaging Camera Bottom View FLIR A35 60mm Thermal Imaging Camera Bottom View
  • FLIR A35 60mm Thermal Imaging Camera  Side View FLIR A35 60mm Thermal Imaging Camera  Side View

FLIR A35 60mm Thermal Imaging Camera

SKU#: 74360-0101

Quick Overview

FLIR A35 60mm Thermal Imaging Camera Highlights:

  • Compact, Versatile Thermal Imaging Temperature Sensors

  • 7.6°(H) × 6.08°(V) FoV

  • High Thermal Sensitivity and Image Quality

  • GigE Vision™ Standard Compatibility

  • GenICam™ Protocol Support

  • 14-bit Temperature Linear Output

  • Synchronization

$5,295.00

Availability: Available

$5,295.00

Details

FLIR A35 60mm Thermal Imaging Camera

Compact, Versatile Thermal Imaging Temperature Sensors

Whether your application is process control/quality assurance, condition monitoring, or fire prevention, the FLIR A35-Series can help your continuous automated processes run smoother. With a more robust design, ten field of view options, and extended operating temperature ranges, the A35 provides enhanced features at a better price. The A35 models are also the only thermal imaging temperature sensors on the market to provide temperature linear output through GenICam™ compliant software.

FLIR A35 60mm Features

Extremely Affordable and Compact

FLIR’s A35-Series models are low-cost thermal imaging temperature sensors that are ideal tools for monitoring temperatures in automation or machine vision environments.


High Thermal Sensitivity and Image Quality

The FLIR A35 60mm produces high quality thermal images that can show temperature differences as small as 50 mK. Record crisp, 640 x 512 pixel thermal images with the FLIR A65, or for less precise applications, the A35 generates 320 x 256 pixel thermal images that still allow you to easily track temperature changes.


GigE Vision™ Standard Compatibility

GigE Vision is a camera interface standard developed using the Gigabit Ethernet communication interface. GigE Vision is the first standard to allow for fast image transfer using low-cost standard cables, even over long distances. With GigE Vision, hardware and software from different vendors can operate seamlessly over Gigabit Ethernet connections.


GenICam™ Protocol Support

The goal of GenICam is to provide a generic programming interface for all types of cameras. Regardless of interface technology (Gigabit Ethernet, Camera Link, IEEE-1394, etc) or features implemented, the Application Programming Interface (API) will always be the same. The GenICam protocol also makes it possible to use third party software with the camera.


14-bit Temperature Linear Output

Allows for non-contact temperature measurement within any third party software. A built-in Gigabit Ethernet connection allows real time 14-bit image streaming to computer.


Synchronization

Possible to configure one camera to be master and others to be slave(s) for applications that call for more than one camera to cover the object or for stereoscopic applications.

Additional Information

Export Controlled No
Product Type No Information Available.
Schematics No Information Available.
View File FLIR A35/A65 Datasheet Size: (195.6 KB)
View File FLIR Automation Catalog Size: (3.61 MB)
View File FLIR IR Camera Player Size: (66.76 MB)

System Overview FLIR A65 FLIR A35
IR resolution 640 × 512 pixels 320 × 256 pixels
Field of View (FOV) 90° × 69° with 7.5 mm lens 63° × 50° with 7.5 mm lens
45° × 37° with 13 mm lens 48° × 39° with 9 mm lens
25° × 20° with 25 mm lens 24° × 19.2° with 19 mm lens
12.4° × 9.92° with 50 mm lens 13° × 10.8° with 35 mm lens
6.2° × 4.96° with 100 mm lens 7.6° × 6.08° with 60 mm lens
Image frequency 30 Hz 60 Hz
Detector data
Detector pitch 17 µm 25 µm
Measurement
Object temperature range -25°C to 135°C (-13 to 275°F) / –40°C to 550°C (-40 to 1022°F)
   
Imaging & Optical Data
Thermal sensitivity/NETD < 0.05°C @ 30°C (86°F) / 50 mK
Accuracy Accuracy ±5°C (±9°F) or ±5% of reading
F-number 1.25
Focus Fixed
Detector data
Focal Plane Array (FPA) / Spectral range Uncooled VOX microbolometer / 7.5–13 µm
Detector time constant Typical 12 ms
Ethernet
Ethernet Control and image
Ethernet, type Gigabit Ethernet
Ethernet, standard IEEE 802.3 / RJ-45
Ethernet, communication GigE Vision ver. 1.2 Client API GenICam compliant
Ethernet, image streaming 8-bit monochrome @ 7.5 / 30 / 60 Hz (variant dependant) Signal linear/ DDE, Automatic/ Manual, Flip H&V 14-bit @ 7.5 / 30 / 60 Hz (variant dependent) according to IR camera resolution Signal linear/ DDE, GigE Vision and GenICam compatible
Ethernet, power Power over Ethernet, PoE IEEE 802.3af class 0 Power
Ethernet, protocols TCP, UDP, ICMP, IGMP, DHCP, GigEVision
Digital input/output
Digital input General purpose , 1× opto-isolated, “0” < 2, “1”=2–12 VDC
Digital output, purpose General purpose output to ext. device (programmatically set)
Digital output 1× opto-isolated, 2–40 VDC, max 185 mA
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 2–40 VDC, max 200 mA
Digital I/O, connector type 12-pole M12 connector (shared with Digital Synchronization and External power)
Synchronization In, purpose Frame sync in to control camera
Synchronization In 1×, non-isolated
Synchronization In, type LVC Buffer @3.3V, “0” <0.8 V, “1”>2.0 V.
Synchronization Out, purpose Frame sync out to control another Ax5 camera
Synchronization Out 1×, non-isolated
Synchronization Out, type LVC Buffer @ 3.3V, ”0”=24 MA max, “1”= –24 mA max.
Digital Synchronization, connector type 12-pole M12 connector (shared with Digital I/O and External power)
Power system
External power operation 12/24 VDC, < 3.5 W nominal < 6.0 W absolute max
External power, connector type 12-pole M12 connector (shared with Digital I/O and Digital Synchronization )
Voltage Allowed range 10–30 VDC
Environmental data
Operating temperature range –15°C to 60°C (+5°F to 140°F)
Storage temperature range –40°C to 70°C (–40°F to 158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity 25°C to 40°C (77°F to 104°F)
EMC EN 61000-6-2 (Immunity) EN 61000-6-3 (Emission) FCC 47 CFR Part 15 Class B (Emission)
Encapsulation IP 40 (IEC 60529)
Bump 25 g (IEC 60068-2-27)
Vibration 2 g (IEC 60068-2-6 & MIL-STD810G)
Physical data
Weight 0.21 kg (0.46 lb.)
Camera size (L × W × H) 106 × 47 × 50 mm (4.2 × 1.9 × 2.0 in.)
Tripod mounting UNC ¼”-20 (on three sides)
Base mounting 4 × M3 thread mounting holes (bottom)
Housing material Magnesium and aluminum
Scope of delivery
Packaging, contents Cardboard box, thermal imaging camera with lens, focus adjustment tool, printed documentation, user documentation CD-ROM, FLIR Tools download card

Available Accessories for the FLIR Boson Thermal Imaging Camera



RC-IF Low Profile VPC USB VPC KIT USB/Analog VPC Kit Boson Development Board USB/CameraLink Board
Power            
Voltage Input 6-26Volts DC 5-26Volts DC 5Volts DC 5Volts DC 5-12Volts DC 5Volts DC

Voltage Output

Regulated 5Volts DC 1.8-3.3Volts DC
Power Via USB
Power 6-Pin JST
Image Control            
FFC Control
DDE Control
AGC Control
Digital Zoom
Continuous Digital Zoom
Flip / Mirror Image VIA GUI
Video via USB
Palette Select via FLIR GUI
Assignable PWM Inputs
Assignable S-Bus Inputs
Video Output            
Digital Video Output
Composite Video Outputs Available 2 2 1 USB Only SDR-26
CameraLink
Interface Options            
80-pin Connection
USB 3 Connection
JST Connection
Serial Communication
SDR-26
100/GigE Ethernet* *
Storage Options
Micro SDCard* *