0item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.
FLIR A310 (30Hz) 18mm Lens 25° FoV Thermal Imaging Camera

FLIR A310 (30Hz) 18mm Lens 25° FoV Thermal Imaging Camera

SKU#: 48201-1101US
$8,995.00

(In stock)

  • FLIR A310 (30Hz) Thermal Imaging Camera FLIR A310 (30Hz) Thermal Imaging Camera
  • FLIR A310 (30Hz) Thermal Imaging Camera in hand FLIR A310 (30Hz) Thermal Imaging Camera in hand

FLIR A310 (30Hz) 18mm Lens 25° FoV Thermal Imaging Camera



30Hz/60Hz Export Controlled Device
Requires validated export license from the U.S. Department of Commerce.

Read More...


SKU#: 48201-1101US

Quick Overview

FLIR A310 (30Hz) Thermal Imaging Camera Highlights

  • IP Thermography Camera

  • 320x240 Resolution

  • 25°(H) × 18.8°(V) FOV

  • MPEG-4 Streamed Video

  • Multiple Lens Options

$8,995.00

Availability: Available

* Required Fields

$8,995.00

Details

Pan Tilt optionalthermal_shots.jpg

FLIR A310 (30Hz) Thermal Imaging Camera

The FLIR A310 18mm thermal imaging camera offers an affordable and accurate temperature measurement for a variety of applications where network capabilities and compliance with network protocols are of importiance. The FLIR A310 18mm thermal imaging camera comes with a 18mm standard lens providing a 25°×19° field of view and 320×240 resolution.

The FLIR A310 18mm has built-in analysis, alarm functionality and independent communication technology over the standard network protocols. The FLIR A310 18mm camera also has all the necessary features and functions to build distributed single or multi-camera solutions utilizing standard ethernet hardware and software protocols.

The FLIR A310 18mm thermal infrarded camera also has built in support to connect to industrial control equipment such as PLCs, and allows for sharing of analysis and alarm results and simple control using the Ethernet/IP and Modbus TCP field bus protocol.

 
FLIR A310 (30Hz) Thermal Imaging Camera tech_thumb

FLIR A310 (30Hz) Key Features

  • MPEG-4 streaming
  • PoE (Power over Ethernet)
  • Built-in web server
  • General purpose I/O
  • 100Mbps Ethernet (100m cable, wireless, fiber, etc.)
  • Synchronization through SNTP
  • Composite video output
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included
  • Built-in Alarm Functions
  • Extensive Analysis Functions

 

FLIR A310 (30Hz) Thermal Imaging Camera in hand

Medical

FLIR A310 (30Hz) Thermal Imaging Camera medical

Infrared thermography is based on analysis of skin surface temperatures as a reflection of normal or abnormal human physiology using a high performance infrared camera.

Safety

FLIR A310 (30Hz) Thermal Imaging Camera safety

In oil/gas production, power generation or distribution there is a need to prevent and detect fires fast and automatically. A fix mounted infrared camera can be installed discretely and almost anywhere to monitor your business.

Education

FLIR A310 (30Hz) Thermal Imaging Camera education

FLIR infrared cameras are being used in university laboratories where high-end academic and applied research is on-going in a wide range of disciplines.

 

Veterinarian

FLIR A310 (30Hz) Thermal Imaging Camera vetrinarian

An animal's body creates heat that fluctuates throughout the body depending on blood flow. The body's recognition of injury and a subsequent increase in blood flow can happen even before the animal shows signs of pain, and other conditions.

Automation

FLIR A310 (30Hz) Thermal Imaging Camera automation

For the automotive industry the ability to continuously and automatically ensure quality is of great importance. A fix mounted infrared camera can be installed almost anywhere to monitor your production process.

Manufacturing

FLIR A310 (30Hz) Thermal Imaging Camera manufacturing

IR cameras made by FLIR have become indispensible tools for many engineering disciplines, particularly in advanced product development.

 

 

Specifications

Imaging and optical data
IR resolution 320 x 240 pixels
Thermal sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Field of view (FOV) 25° × 18.8°
Minimum focus distance 0.04 m (1.31 ft.)
Focal length 18 mm (0.7 in.)
Spatial resolution (IFOV) 1.36 mrad
Lens identification Automatic
F-number 1.3
Image frequency 30 Hz
Focus Automatic or manual (built in motor)
Zoom 1-8x continuous, digital, interpolating zooming on images
Detector data  
Detector type Focal plane array (FPA), uncooled microbolometer
Spectral range 7.5–13 µm
Detector pitch 25µm
Detector time constant Typical 12 ms
Measurement  
Object temperature range
  • –20 to +120°C (–4 to +248°F)
  • 0 to +350°C (+32 to +662°F)
Accuracy ±2°C (±3.6°F) or ±2% of reading
Measurement analysis  
Spotmeter 10 (with no image streaming)
Area 10 boxes with max./min./average/position (with no image streaming)

Isotherm

1 with above/below/interval
Measurement option Measurement Mask Filter
Schedule response: File sending (ftp), email (SMTP)
Difference temperature Delta temperature between measurement functions or reference temperature
Reference temperature Manually set or captured from any measurement function
Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reflected apparent temperature correction Automatic, based on input of reflected temperature
External optics/windows correction Automatic, based on input of optics/window transmission and temperature
Measurement corrections Global and individual object parameters
Alarm  
Alarm Functions 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Set-up  
Color palettes Color palettes (BW, BW inv, Iron, Rain)
Set-up commands Date/time, Temperature (°C/°F)
Storage of images Built-in memory for image storage
Storage media Standard JPEG, 16-bit measurement data included
File formats  
   
   
Ethernet  
Ethernet Control, result and image
Ethernet, type 100 Mbps
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, communication TCP/IP socket-based FLIR proprietary
Ethernet, video streaming

JPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5

Ethernet, image streaming 16-bit 320 × 240 pixels @ 7-8 Hz
  • Radiometric
Ethernet power

Power over Ethernet, PoE IEEE 802.3af class 0.

NOTE: In cameras manufactured before 2013, due to an error in the implementation of power over Ethernet, in some rare cases the
camera will not be powered. In such cases, power the camera using the external power cable, or modify the camera according to Service bulletin SB14-006.
Ethernet, protocols

Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP,
HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP

Digital input/output  
Digital input, purpose Image tag (start/stop/general), Input ext. device (programmatically read)
Digital input 2 opto-isolated, 0–1.5 V = low, 3–25 V = high
Digital output, purpose As function of ALARM, Output to ext. device (programmatically set)
Digital output 2 opto-isolated, ON = supply (max. 100 mA), OFF = open
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 6–24 VDC, max. 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Composite video  
Video out Composite video output, PAL and NTSC compatible
Video, standard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Video, connector type Standard BNC connector
Power system  
External power operation 12/24 VDC, 24 W absolute max.
External power, connector type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC
Environmental data  
Operating temperature range –15°C to +50°C (+5°F to +122°F)
Storage temperature range –40°C to +70°C (–40°F to +158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
EMC
  • EN 61000-6-2:2001 (Immunity)
  • EN 61000-6-3:2001 (Emission)
  • FCC 47 CFR Part 15 Class B (Emission)
Encapsulation IP 40 (IEC 60529)
Shock 25 g (IEC 60068-2-27)
Vibration 2 g (IEC 60068-2-6)
Physical data  
Weight 0.7 kg (1.54 lb.)
Camera size (L × W × H) 170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)
Tripod mounting UNC ¼"-20 (on three sides)
Base mounting 2 × M4 thread mounting holes (on three sides)
Housing material Aluminum
What's in the Box  
List of contents
            • Infrared camera with lens
            • Ethernet cable
            • Mains cable
            • Power cable, pig-tailed
            • Power supply
            • Printed documentation
            • Utility CD-ROM
View File FLIR A300 Size: (9.4 MB)
View File FLIR Automation Catalog Size: (3.61 MB)

FLIR A300 Series Thermal Camera What's in the Box

Click Photo to Enlarge